Window Leak Testing

Advanced window and fenestration leak investigation services to identify perimeter failures, flashing deficiencies, and installation errors across BC.

Window leak testing is a specialized diagnostic service focusing on fenestration assemblies including windows, sliding doors, and fixed glazing systems. Our technicians use controlled water spray testing combined with interior moisture detection to pinpoint the exact source of water intrusion in window installations.

Window leaks are among the most common building envelope failures in BC's wet climate. Improper installation, inadequate flashing, perimeter seal degradation, and missing sill pans are frequent causes of water infiltration that can lead to structural framing damage, insulation saturation, and interior mold growth. Early detection through professional window leak testing prevents escalating repair costs and building deterioration.

Our Testing Process

1

Window Assembly Inspection

Comprehensive visual assessment of window installation details, flashing integration, perimeter seals, and potential failure indicators.

2

Controlled Spray Testing

ASTM-compliant water application targeting window perimeters, sill conditions, head details, and jamb interfaces using calibrated spray equipment.

3

Interior Leak Detection

Real-time monitoring during testing to observe active leakage, identify water entry points, and document failure mechanisms.

4

Diagnostic Report & Repair Guidance

Detailed engineering report with findings, root cause analysis, photographic documentation, and specific repair recommendations for contractors.

Common Applications

Perimeter Seal Failure

Testing window frame-to-wall interface conditions where sealant deterioration or improper installation allows water penetration.

Flashing System Deficiencies

Identifying missing, damaged, or improperly integrated flashing components at window head, sill, and jamb locations.

Sill Pan & Drainage Issues

Assessing sill pan installation, drainage path obstructions, and water management at the base of window assemblies.

Glazing & Gasket Leaks

Evaluating glazing seal integrity, gasket condition, and weatherstrip performance in operating window components.

Why Choose EnvelopeTesting.ca?

25+ years of window and fenestration diagnostics experience

ASTM E1105 compliant testing methodology

Work with window manufacturers, architects, and contractors

Insurance-grade documentation for warranty claims

Thermal imaging to detect concealed moisture damage

Schedule Your Building Envelope Assessment

Professional building envelope diagnostics across British Columbia.